Control Voltage: Line 24V (18-30 VAC) 50-60Hz
Anticipator Setting: 0.1A plus valve load @ 24 VAC
Trial For Ignition: 15 or 90 Seconds (switch selectable)
Operating Temperature: -40° to 165°F
Relative Humidity: 0% to 95% non condensing
* Single rod (local sense) or two rod (remote sense) flame sensing
* Non-100 percent shutoff, 100 percent shutoff/lockout, or 100 percent shutoff/continuous retry
* Natural or LP gas
* Shutoff/lockout times of 15 seconds or longer
* Pre-purge configurable to 30 seconds or no prepurge
* Pilot burners with flow rates of 1,500 Btuh or less
* With or without integral damper connector
- Universal intermittent pilot gas ignition control
- Provides ignition sequence, flame monitoring and safety shutoff for single/dual rod intermittent pilot control applications
- For gas fired furnaces, boilers and other heating applications
- Switch selectable pre-purge and ignition trials with permanent lock
- Works with or without vent damper connected
- Works with both Natural and LP gas systems